UL UL 60079-5:2020

UL 60079-5:2020 PDF Download

Standard EN Sample
UL 60079-5:2020 Sample

Explosive Atmospheres - Part 5: Equipment protection by powder filling 'q'

SKU133991925 Published by Underwriters Laboratories Inc. UL Publication Date2020-08-14 Pages CountPages34

1 Scope

Modification of Clause 1, first paragraph to replace with the following:

1.1 This

standard

part of IEC 60079

contains specific requirements for the construction, testing and marking of electrical equipment, parts of electrical equipment and Ex components in the type of protection powder filling “q”, intended for use in explosive gas atmospheres.

NOTE 1 Electrical equipment and Ex components protected by powder filling “q” can contain electronic circuits, transformers, protection fuses, relays, intrinsically safe electrical apparatus, associated electrical apparatus, switches, etc.

NOTE 2 Type of protection powder filling “q” provides Equipment Protection Level (EPL) Gb or Mb.

Modification of Clause 1, second paragraph to replace with the following:

1.1 This standard supplements and modifies the general requirements of

UL 60079-0

IEC 60079-0

. Where a requirement of this standard conflicts with a requirement of

UL 60079-0

IEC 60079-0

, the requirement of this standard takes precedence.

This standard applies to electrical equipment, parts of electrical equipment and Ex components with:

– a rated supply current less than or equal to 16 A;

– a rated supply voltage less than or equal to 1 000 V;

– a rated power consumption less than or equal to 1 000 W.

Details
Edition4
Language(s)English
File Size317.4 KB
Purchase Right after completing the purchase process, you will immediately get a digital copy of this standard which is: Not Locked Printable Multi-User $ 42.00