IEC 61008-1:2010+AMD1:2012+AMD2:2013 CSV PDF Download
Standard ENFR Sample 1 Sample 2 Sample 3 EN FRResidual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs) - Part1: General rules
Also Known As:
SKU169476174
Published by
International Electrotechnical Commission
IEC
Publication Date2013-09-12
Pages CountPages686
IEC 61008-1:2010+A1:2012+A2:2013 applies to residual current operated circuit-breakers functionally independent of, or functionally dependent on, line voltage, for household and similar uses, not incorporating overcurrent protection (hereafter referred to as RCCBs), for rated voltages not exceeding 440 V a.c. with rated frequencies of 50 Hz, 60 Hz or 50/60 Hz and rated currents not
exceeding 125 A, intended principally for protection against shock
hazard. This third edition cancels and replaces the second edition
published in 1996, amendment 1 (2002) and amendment 2 (2006). This
edition constitutes a technical revision. This edition includes the
following significant technical changes with respect to the previous
edition:
- complete revision of EMC sequences, including the new test T.2.6 already approved in IEC 61543;
- clarification of RCDs current/time characteristics reported in Tables 1 and 2;
- revision of test procedure for I?n between 5 A and 200 A;
- testing procedure regarding the 6mA d.c. current superimposed to the fault current;
- improvement highlighting RCDs with multiple sensitivity;
- tests for the use of RCCBs in IT systems.
This consolidated version consists of the third edition (2010), its amendment 1 (2012), its amendment 2 (2013) and the corrigendum of January 2014. Therefore, no need to order amendments in addition to this publication.
- complete revision of EMC sequences, including the new test T.2.6 already approved in IEC 61543;
- clarification of RCDs current/time characteristics reported in Tables 1 and 2;
- revision of test procedure for I?n between 5 A and 200 A;
- testing procedure regarding the 6mA d.c. current superimposed to the fault current;
- improvement highlighting RCDs with multiple sensitivity;
- tests for the use of RCCBs in IT systems.
This consolidated version consists of the third edition (2010), its amendment 1 (2012), its amendment 2 (2013) and the corrigendum of January 2014. Therefore, no need to order amendments in addition to this publication.
Details
History and complementary documents
History
Edition | 3.2 |
ICS Codes | 29.120.50 - Fuses and other overcurrent protection devices |
Language(s) | English + French |
File Size | 6.6 MB |
Purchase
Right after completing the purchase process, you will immediately get a digital copy of this standard which is:
Not Locked
Printable
Multi-User
$
179.00