ICEA S-76-474:2011 PDF Download
Standard EN SampleNeutral-Supported Power Cable Assemblies with Weather-Resistant Extruded Insulation Rated 600 Volts
Also Known As:
SKU919229716
Published by
Insulated Cable Engineers Association
ICEA
Publication Date2011
Pages CountPages33
This standard applies to the materials, constructions, and
testing of assemblies of extruded dielectric insulated electric
current carrying phase conductors and bare or covered neutral
electrical conductors used as weather-resistant wires and cables
suspended from supporting structures for the overhead distribution
of electrical energy.
This standard is intended to apply to the following multiplexed wire and cable constructions:
Neutral Supported Service Drop Cables, and
Neutral Supported Secondary Distribution Cables.
The use of these service drop and secondary distribution cables is limited to Circuits not exceeding 600 volts phase-to-phase, or 480 volts phase-to-ground, and to a normal service conductor temperature rating of 75°C or 90°C.
When reference is made in this publication to an industry standard, that reference is to the standard with title and date of issue listed in Appendix A. Where a conflict exists between the requirements of this standard and those of a referenced standard, the requirements of this standard shall apply.
In this standard, units are most often expressed in the English System. To convert from an English unit to the appropriate metric unit, multiply the value of the English unit by the appropriate number from Appendix B.
The recommended bending radii for phase conductors and cable assemblies is given in Appendix C.
U.S. customary units, except for temperature, are specified throughout this standard. Approximate International System of Units (SI) equivalents are included for information only.
This standard is intended to apply to the following multiplexed wire and cable constructions:
Neutral Supported Service Drop Cables, and
Neutral Supported Secondary Distribution Cables.
The use of these service drop and secondary distribution cables is limited to Circuits not exceeding 600 volts phase-to-phase, or 480 volts phase-to-ground, and to a normal service conductor temperature rating of 75°C or 90°C.
When reference is made in this publication to an industry standard, that reference is to the standard with title and date of issue listed in Appendix A. Where a conflict exists between the requirements of this standard and those of a referenced standard, the requirements of this standard shall apply.
In this standard, units are most often expressed in the English System. To convert from an English unit to the appropriate metric unit, multiply the value of the English unit by the appropriate number from Appendix B.
The recommended bending radii for phase conductors and cable assemblies is given in Appendix C.
U.S. customary units, except for temperature, are specified throughout this standard. Approximate International System of Units (SI) equivalents are included for information only.