HI 9.6.9-2013 PDF Download
Standard EN SampleAmerican National Standard for Rotary Pumps - Guidelines for Condition Monitoring
Also Known As: ANSI/HI 9.6.9
Full Description
This new guideline was released in 2013 to discuss condtion monitoring in rotary pumps for both sealed and sealless pump designs. It should be noted that there is a separate standard available which covers the Rotodynamic pumps. While monitoring is not a requirement, this guideline sets strategies for when and how to monitor pumps. Control limits have been recommended, where appropriate, for those indicators whose limits are not defined in other Hydraulic Institute Standards. Various failure modes can be characterized by the following observations and processes:
- Power Absorbed
- Temperature
- Leakage
- Pressure (Suction, Discharge, Differential)
- Vibration
- Rate of Flow
- Speed (RPM)
Details
History and complementary documents
History
Language(s) | English |
ISBN | 9781935762201 |
File Size | 1.4 MB |
Purchase
Right after completing the purchase process, you will immediately get a digital copy of this standard which is:
Not Locked
Printable
Multi-User
Scanned
$
16.50